Relight and time the drop
Light the pilot per the sticker inside the access panel. Note the second the flame catches. A thermocouple on the way out will drop the flame in under 5 minutes the first time, faster each subsequent relight.
A healthy thermocouple holds the gas valve open with just 25 millivolts. When it gets weak or crusted, the pilot drops out minutes to hours after relight. $205 flat, 30 minutes on the truck.

Confirm it’s the thermocouple
Thermocouples fail in a specific pattern. If yours matches, a $20 part and 30 minutes fixes it.
Light the pilot per the sticker inside the access panel. Note the second the flame catches. A thermocouple on the way out will drop the flame in under 5 minutes the first time, faster each subsequent relight.
Thermocouple tip should sit in the hottest part of the flame (a steady blue inner cone). If the flame is yellow, lazy, or lifting off the pilot tube, it may be a pilot orifice problem instead ($240 pilot assembly) not a thermocouple ($205).
Hold the gas valve knob to PILOT, press the red igniter button. A sharp click and visible spark means the piezo igniter is fine, so the problem is downstream at the thermocouple or pilot. No click means the igniter is bad: $240 pilot assembly.
When it’s not the thermocouple
A failed pilot orifice means a $240 full pilot assembly swap. A failing gas valve throws the pilot and also drops temperature mid-shower: $310 for valve + thermostat. A clogged flue drops combustion air, and newer FVIR (flammable vapor ignition resistant) tanks shut the pilot down when the base intake gets dust-plugged: a $220 flush + flue test fixes it.
No dispatchers, no “a technician has been assigned,” no four-hour window. You get a photo of the actual tech by text 30 minutes before arrival, and you keep that tech’s name and number for the next time.

“Called at 9, Ameer was here by 10:30 with the exact tank, quote on the spot, done by 1. No bait and switch. Real pricing.”
Jon R., Mountain View, Oct 2026
“Honest call on repair vs replace. He showed me the sediment at the base and we picked the heat pump with the rebate. Netted $1,400 out the door.”
Priya S., 94040, Sep 2026
“Pilot kept dropping, thought I needed a new tank. Got a $205 thermocouple instead. Still running strong 4 months later.”
David L., 94043, Aug 2026
Related
Before you book
6 to 10 years in a well-maintained tank. Debris on the tip and a slow pilot flame shortens it. If you have been relighting the pilot 2 or 3 times a year, replace it.
If you’re comfortable shutting off gas, you can. A $15 to $25 universal thermocouple at the hardware store and 20 minutes with a wrench. If anything about gas lines makes you uneasy, our $205 flat includes the leak test on the pilot connection.
Downdraft through the flue. A venting cap or draft-diverter cone fixes it. Different from a thermocouple failure, but same symptom: schedule a diagnostic if the pattern tracks weather.
$205 thermocouple, $240 pilot assembly, $310 gas valve. Named tech at the door, price in writing.